Language: English · 阅读本页中文版
Kitchen Fire Suppression 3-Tag Separator & Semi-Annual Inspection Planner
Select your US jurisdiction (50 states + DC), separate your hood suppression tag from hood washing and Class K extinguishers, check UL 300 readiness, and schedule 30/7/1-day reminders.
Six months after the last tag date is filled in below. You can change it.
NFPA 96 states that fire-extinguishing systems should be maintained by properly trained, qualified, and certified person(s) at least every six months. Markel, read 2026-11-13. Reminders use the date you enter. Source.
Worksheet preview
Add the last tag date, or choose a next date, and the countdown fills in.
Block 1. Hood suppression file card
Location or hood: UL 300 Cookline
System brand entered: not entered
People search this brand. We are not affiliated.
Markel reading, read 2026-11-13: at least every six months, by a person trained on that system
Source: https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants
Next date you entered: not entered
Block 2. Three-tag separator and technician questions
This tag is the suppression inspection, not hood cleaning, not the hand extinguisher
Ask whether the technician is authorized for the brand they typed
[ ] Confirmed technician holds current training/authorization for our specific suppression brand
[ ] Verified fusible links / nozzles / manual pull station check is included on the service report
[ ] Separated this suppression inspection tag from hood grease-cleaning schedule
[ ] Checked portable Class K wet-chemical extinguisher tag separately
[ ] Confirmed where the signed semi-annual inspection report is stored on-site
Block 3. Suppression tag log
Inspection date | Service company and tech cert | Links or caps replaced | Tag next-due | Report location
________ | ________ | ________ | ________ | ________
________ | ________ | ________ | ________ | ________
Block 4. Disclaimer
We do not dispatch a technician. Ansul is not in our name
This file is not an official certificate.
Prepared by Kitchen Suppression Due (kitchensuppressiondue.com). Source notes read 2026-11-13. We are not a fire-protection contractor; Ansul; NFPA; the fire marshal.
Best-fit self-serve plan for your setup
Best fit for 1 hood: Annual ($39/year, default) or Lifetime ($299 one-time) with 30/7/1-day reminders.
The email contains this worksheet. This plan also emails you 30, 7, and 1 day before the date you entered.
UL 300 commercial kitchen fire suppression readiness checklist
UL 300 is the fire-testing listing standard for wet-chemical extinguishing systems protecting modern high-efficiency commercial cooking equipment, insulated deep fryers, and vegetable cooking oils. Markel's reading of NFPA 96, read 2026-11-13, states that fire-extinguishing systems should be maintained by properly trained, qualified, and certified persons at least every six months: https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants
Unlike legacy dry-chemical hoods built decades ago for slower-cooling animal fats, UL 300 wet-chemical systems discharge a potassium-based saponifying agent engineered to blanket hot cooking oil, react with surface fats to form a vapor-sealing foam layer, and cool the appliance below auto-ignition temperature while cutting fuel or electric power. Kitchen Suppression Due is an independent digital publisher—not UL Solutions, NFPA, Ansul, or a fire-protection contractor.
Use the UL 300 workspace above or checklist pricing to log your hood brand, cooking-line layout status, last tag date, and next six-month service target into a printable PDF worksheet with optional 30, 7, and 1 day email reminders.
Related guidance
Kitchen fire suppression six-month guide
Review the cited NFPA 96 six-month rule and three-record separation.
Hood suppression tag and fusible link tracker
Log system brand nameplates, link replacement dates, and cartridge notes.
Audit-ready kitchen hood inspection binder
Organize UL 300 reports, hood grease cleaning, and Class K logs.
Multi-unit restaurant suppression tracker
Track UL 300 six-month tags across up to five restaurant locations.
Why hood cleaning is not suppression inspection
Keep exhaust duct washing separate from fixed wet-chemical service.
California commercial kitchen suppression guide
See state-specific AHJ portal and Title 19 planning notes.
UL 300 厨房灭火喷嘴与易熔片中文核对表 (ZH)
Read the full Chinese-language counterpart to this UL 300 checklist.
PDF checklist and 30/7/1-day reminder plans
Compare $19 one-time, $39/year personal, and $149/year multi-location plans.
Why UL 300 wet-chemical protection depends on your exact cooking-line map
A UL 300 commercial hood suppression system is not an open-room sprinkler head that sprays evenly everywhere. Each overhead appliance drop is piped, sized, and aimed for the specific hazard sitting directly underneath it—whether a high-recovery twin-vat fryer, a high-BTU Chinese wok ring, a radiant lava-rock or cast-iron charbroiler, an upright salamander, a flat-top griddle, or an open-top six-burner range.
Because nozzle flow rates, discharge cones, and vertical distances are engineered from the manufacturer’s UL 300 design manual for that exact lineup, sliding a fryer eighteen inches down the line or swapping a range for a charbroiler changes the hazard geometry immediately. Never treat a cooking-appliance swap as a purely plumbing or culinary decision; alert an authorized suppression contractor before operating a rearranged line.
Caster wheel stops, gas-hose restraints, and nightly cleaning drift
Most modern commercial fryers, ranges, and broilers sit on heavy-duty casters so line cooks can pull equipment forward to degrease walls and sweep behind gas manifolds. Without painted floor markers, curbing, or mechanical wheel stops anchored to the quarry tile, appliances gradually creep sideways over weeks of nightly cleaning until a fryer vat straddles the gap between two nozzles.
Before your six-month service visit, stand in front of the cooking bank and visually trace each drop pipe straight down toward the appliance below without touching or twisting any nozzle. Confirm that quick-disconnect flexible gas hoses have intact restraining tether cables shorter than the gas connector, and verify that every castered unit sits squarely inside its intended floor position.
Nozzle blow-off caps: the tiny part that prevents grease-plugged orifices
Every UL 300 wet-chemical nozzle inside a greasy hood canopy or above a cooking surface relies on a small rubber, silicone, or tethered metal blow-off cap fitted over the nozzle tip. In normal operation, that cap seals vaporized fryer oil, wok smoke, and hood-cleaning detergent out of the precision internal swirl chamber; if the system actuates, agent pressure pops the cap off in a fraction of a second.
When a blow-off cap falls into a stockpot or gets knocked off by a long-handled scrub brush, airborne grease enters the bare nozzle bore and bakes into a hard plug. Train kitchen leads never to wipe nozzles aggressively, never to wrap foil around suppression drops, and to ask the authorized technician during every six-month visit to verify cap condition and replace aged elastomer caps per manufacturer schedules.
Plenum nozzles, exhaust duct collars, and fusible link detection paths
In addition to appliance-specific drops, a UL 300 hood system protects the grease-collection plenum behind the baffle filters and the exhaust duct collar rising toward the rooftop fan. Thermal fusible links or mechanical/electric heat detectors suspended in the plenum and duct collar sense abnormal fire heat and release tension on the stainless detection cable to fire the system automatically.
Between six-month inspections, grease buildup on baffle filters or missing filters exposes plenum links to excess cooking vapor and stray flame flare-ups. Keep a complete bank of listed baffle grease filters seated tightly in the hood track at all times, and ask your technician to itemize fusible link temperature ratings and replacement counts on your written six-month service report; see our tag and fusible link guide.
Manual pull stations and automatic gas or electric shunt-trip interlocks
Two operational interlocks are checked alongside nozzles and links during a semi-annual visit. First, the remote manual pull station—typically mounted along the path of egress away from the cooking line—must remain completely unobstructed by flour bins, linen hampers, or delivery hand trucks, with staff able to see and reach it immediately. Second, system actuation must automatically shut off all fuel and electrical power to cooking appliances under that hood.
If your line mixes gas fryers with electric countertop induction units, food warmers, or electric salamanders positioned beneath the canopy, verify with your contractor whether both the gas shutoff valve and the electrical shunt-trip breaker are interlocked. Coordinate testing before morning prep flames are lit and place any connected central-station fire-alarm account on test beforehand.
Pairing your UL 300 fixed system with a Class K portable extinguisher
Commercial fire codes pair UL 300 fixed wet-chemical hood protection with a portable Class K wet-chemical fire extinguisher mounted near the kitchen path of travel, and post placard instructions reminding kitchen staff that the manual hood suppression system should be actuated before using a portable Class K extinguisher on a cooking-oil fire.
Never substitute a dry-chemical ABC hallway extinguisher for a Class K kitchen unit, and keep the annual portable extinguisher tag separate from your six-month fixed hood suppression report inside your four-tab kitchen fire binder. Bilingual teams can also share our Chinese UL 300 checklist (/zh/ul-300-checklist) with wok and line leads.
Questions
What does UL 300 mean on a commercial kitchen fire suppression system?
UL 300 is the fire-testing standard for wet-chemical extinguishing systems protecting commercial cooking equipment and modern vegetable oils. A UL 300 listed system uses engineered wet-chemical nozzles, detection linkage, and fuel shutoffs.
What happens if we swap or move a fryer under a UL 300 hood?
Moving or swapping cooking appliances can place high-hazard vats or broilers outside their listed nozzle coverage. Notify a brand-authorized fire-protection contractor whenever cooking-line layout or appliance types change.
Can kitchen staff replace missing nozzle blow-off caps themselves?
No. Different nozzle models require manufacturer-specified caps so discharge pressure releases properly. Report missing caps to an authorized suppression technician rather than taping or capping nozzles with makeshift materials.
How often should a UL 300 kitchen hood suppression system be inspected?
Public guidance citing NFPA 96 (Markel, read 2026-11-13) states fire-extinguishing systems should be maintained at least every six months by properly trained, qualified, and certified persons. Confirm local AHJ and manufacturer rules.
Does Kitchen Suppression Due certify UL 300 compliance?
No. We are an independent digital publisher. Our PDF checklist and 30/7/1-day email reminders help managers organize pre-visit questions and dates; only a qualified technician and your local AHJ can evaluate compliance.