Language: English · 华人餐馆中文指南 (/zh)
Kitchen Fire Suppression 3-Tag Separator & Semi-Annual Inspection Planner
Select your US jurisdiction (50 states + DC), separate your hood suppression tag from hood washing and Class K extinguishers, check UL 300 readiness, and schedule 30/7/1-day reminders.
Six months after the last tag date is filled in below. You can change it.
NFPA 96 states that fire-extinguishing systems should be maintained by properly trained, qualified, and certified person(s) at least every six months. Markel, read 2026-11-13. Reminders use the date you enter. Source.
Worksheet preview
Add the last tag date, or choose a next date, and the countdown fills in.
Block 1. Hood suppression file card
Location or hood: Main Cookline Hood
System brand entered: not entered
People search this brand. We are not affiliated.
Markel reading, read 2026-11-13: at least every six months, by a person trained on that system
Source: https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants
Next date you entered: not entered
Block 2. Three-tag separator and technician questions
This tag is the suppression inspection, not hood cleaning, not the hand extinguisher
Ask whether the technician is authorized for the brand they typed
[ ] Confirmed technician holds current training/authorization for our specific suppression brand
[ ] Verified fusible links / nozzles / manual pull station check is included on the service report
[ ] Separated this suppression inspection tag from hood grease-cleaning schedule
[ ] Checked portable Class K wet-chemical extinguisher tag separately
[ ] Confirmed where the signed semi-annual inspection report is stored on-site
Block 3. Suppression tag log
Inspection date | Service company and tech cert | Links or caps replaced | Tag next-due | Report location
________ | ________ | ________ | ________ | ________
________ | ________ | ________ | ________ | ________
Block 4. Disclaimer
We do not dispatch a technician. Ansul is not in our name
This file is not an official certificate.
Prepared by Kitchen Suppression Due (kitchensuppressiondue.com). Source notes read 2026-11-13. We are not a fire-protection contractor; Ansul; NFPA; the fire marshal.
Best-fit self-serve plan for your setup
Best fit for 1 hood: Annual ($39/year, default) or Lifetime ($299 one-time) with 30/7/1-day reminders.
The email contains this worksheet. This plan also emails you 30, 7, and 1 day before the date you entered.
Commercial hood suppression 6-month tag & fusible link tracker
Restaurant owners and general managers routinely type "Ansul inspection" or "R-102 tag" into search engines when looking for a six-month commercial range-hood fire suppression inspection—much like calling any adhesive bandage by a famous brand name. Scope notice: Kitchen Suppression Due is an independent digital checklist publisher and is NOT affiliated with, endorsed by, sponsored by, or authorized by Ansul, Johnson Controls, Tyco, Pyro-Chem, Range Guard, Amerex, Buckeye, or Kidde.
Regardless of which manufacturer built the stainless wet-chemical cabinet mounted on your kitchen wall, Markel's reading of NFPA 96, read 2026-11-13, states that fire-extinguishing systems should be maintained by properly trained, qualified, and certified persons at least every six months: https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants
Use the tag-tracking workspace above or checklist pricing to record the exact brand copied off your cabinet nameplate, your last tag date, fusible-link notes, and your next six-month target date into a private PDF preparation sheet with optional 30, 7, and 1 day email reminders.
Related guidance
Kitchen fire suppression inspection overview
See the six-month NFPA 96 source quote and interactive date calculator.
Restaurant suppression tag is not hood cleaning
Separate hood grease-cleaning invoices from suppression and Class K tags.
UL 300 wet-chemical nozzle and cap checklist
Verify appliance alignment, blow-off caps, and fuel shutoff prompts.
Kitchen fire and health inspection binder
Set up a shift-proof four-tab binder for inspectors and managers.
Multi-unit restaurant hood renewal tracker
Track staggered six-month tags across up to five restaurant locations.
Texas commercial kitchen suppression guide
Review SFMO licensing, tag colors, and municipal portal notes.
Non-affiliation and scope disclaimer
Read our full brand independence and non-contractor scope statement.
PDF checklist and reminder plan pricing
Compare $19 one-time, $39/year annual, and $149/year multi-location plans.
Why copying the real cabinet nameplate beats guessing a brand name
Commercial kitchens across the United States operate several distinct pre-engineered wet-chemical hood suppression platforms—each using proprietary nozzles, blow-off caps, detection brackets, expellant gas cartridges or stored-pressure tanks, and manufacturer service manuals. Calling a fire-protection office and asking generically for an "Ansul check" when your wall cabinet actually carries a different manufacturer’s label can result in a technician arriving without the right factory training card or replacement parts.
Before placing your booking call, walk up to the red or stainless suppression cabinet mounted near the hood, wipe grease film gently off the exterior data plate (never open the sealed mechanism housing), and take a clear smartphone photo showing the manufacturer name, model designation, and serial identifier. Read that exact brand and model to the service dispatcher and ask in plain words: is the technician assigned to our visit currently authorized for this exact brand?
How to read the six-month hanging tag without missing critical fields
After completing a semi-annual maintenance visit, a licensed technician punches or writes the service month, day, and year on a hanging inspection tag attached near the cabinet or manual pull path and issues a detailed written or digital service report. A hanging cardboard or plastic tag exposed to dish-pit steam and kitchen traffic can tear off or fade long before your next inspection walk-through.
Never treat the hanging tag alone as your entire compliance archive. Before signing the work tablet, verify that your customer report matches the date punched on the tag, names your exact street address and hood line (for example "Main Cookline" vs. "Prep Kitchen Bake Hood"), lists the technician’s license or certification number, and clearly distinguishes routine passing maintenance from any open follow-up items.
Fusible links and thermal detectors: questions to ask on your report
Fixed wet-chemical hood systems rely on metal alloy fusible links—or fixed-temperature bulb/electric thermal detectors—mounted inside the hood plenum and exhaust duct collar to melt or trip at a rated temperature when a grease fire erupts. Over months of high-heat broiling, frying, and caustic hood washing, grease residue and thermal cycling fatigue link assemblies.
Industry standards (including NFPA 17A / NFPA 96 maintenance practices and manufacturer manuals) establish strict replacement schedules for fusible links and specific inspection rules for fixed-temperature detectors. Ask your service office before booking whether link replacement is bundled into the flat inspection fee or billed per link, and verify after the visit that the service report records the link temperature ratings and year stamps installed.
Expellant cartridges, wet-chemical tanks, and multi-year cylinder dates
Depending on system architecture, a commercial hood cabinet either uses a nitrogen/CO2 expellant gas cartridge to pressurize a non-pressurized stainless wet-chemical tank upon actuation, or stores wet-chemical agent inside a factory-pressurized cylinder with a visual pressure gauge. Both designs carry multi-year manufacturer maintenance milestones—such as periodic wet-chemical agent checks, regulator tests, or 12-year hydrostatic tank testing—beyond the routine six-month visit.
Ask your technician to note the manufacture or last hydrostatic test year stamped on the tank/cartridge shoulder inside your written service report. Logging that multi-year milestone alongside your six-month tag prevents a surprise big-ticket cylinder overhaul caught during a rushed property sale or lease renewal.
Separating the hood suppression tag from portable extinguishers and duct washing
Many fire-equipment companies service both fixed range-hood wet-chemical cabinets and portable Class K / Class ABC hand extinguishers during the same morning stop, while a separate exhaust-cleaning contractor pressure-washes the canopy and vertical grease duct overnight. Even when two services appear on one vendor invoice, inspectors check three separate tags.
Use our three-tag comparison and our four-tab binder checklist so every invoice line item maps to the right asset—and review our UL 300 nozzle & layout checklist whenever cooking appliances move.
How our independent PDF log and 30/7/1-day reminders work
Kitchen Suppression Due never sells replacement parts, never dispatches technicians, never claims manufacturer affiliation, and never shares your email with lead brokers. Our tool prints the brand, last tag date, target next date, location label, and pre-visit verification prompts you enter onto a clean four-block PDF worksheet.
Choose $19 once for a single PDF, $39/year for one hood with 30, 7, and 1 day email reminders, $299 for lifetime single-hood reminders, or $149/year and $999 multi-location plans for up to five kitchens.
Questions
Is Kitchen Suppression Due affiliated with Ansul or Johnson Controls?
No. Kitchen Suppression Due is a completely independent digital checklist publisher. Ansul is a registered trademark of its respective owner; we are not affiliated with, endorsed by, or authorized by any fire-equipment manufacturer.
Why should I photograph the suppression cabinet nameplate before calling a vendor?
Commercial kitchens use many different wet-chemical brands and models. A clear photo lets you verify that the dispatched technician holds active training and carries parts for the actual equipment in your kitchen.
How often are commercial hood suppression tags renewed?
Public guidance citing NFPA 96 (Markel, read 2026-11-13) states fire-extinguishing systems should be maintained at least every six months by properly trained, qualified, and certified persons. Verify local AHJ and manufacturer schedules.
Are fusible links included automatically in every inspection quote?
Not always. Some contractors quote a base inspection fee and itemize fusible links, blow-off caps, and portal upload fees separately. Ask on the phone before booking so there are no invoice surprises.
Does your PDF replace the technician’s hanging service tag?