Language: English · 华人餐馆中文指南 (/zh)
Kitchen Fire Suppression 3-Tag Separator & Semi-Annual Inspection Planner
Select your US jurisdiction (50 states + DC), separate your hood suppression tag from hood washing and Class K extinguishers, check UL 300 readiness, and schedule 30/7/1-day reminders.
Texas (TX) — Texas State Fire Marshal’s Office (TDI SFMO — Insurance Code Ch. 6001 / 28 TAC Ch. 34) & municipal fire marshals
Plan around a six-month fixed hood suppression inspection interval in Texas under NFPA 96 / NFPA 17A practices, kept separate from hood grease cleaning and portable Class K extinguisher tags.
Hundreds of Texas municipal fire marshals (DFW, Houston, Austin, San Antonio suburbs) track 6-month kitchen hood tags via The Compliance Engine, alongside SFMO service tag color rules.
General operational planning reference only, not legal advice. Local fire marshals (AHJs), state fire code amendments, and equipment manufacturer manuals control.
Six months after the last tag date is filled in below. You can change it.
NFPA 96 states that fire-extinguishing systems should be maintained by properly trained, qualified, and certified person(s) at least every six months. Markel, read 2026-11-13. Reminders use the date you enter. Source.
Worksheet preview
Add the last tag date, or choose a next date, and the countdown fills in.
Block 1. Hood suppression file card
Location or hood: TX Kitchen Hood
System brand entered: not entered
People search this brand. We are not affiliated.
Markel reading, read 2026-11-13: at least every six months, by a person trained on that system
Source: https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants
Next date you entered: not entered
Block 2. Three-tag separator and technician questions
This tag is the suppression inspection, not hood cleaning, not the hand extinguisher
Ask whether the technician is authorized for the brand they typed
[ ] Confirmed technician holds current training/authorization for our specific suppression brand
[ ] Verified fusible links / nozzles / manual pull station check is included on the service report
[ ] Separated this suppression inspection tag from hood grease-cleaning schedule
[ ] Checked portable Class K wet-chemical extinguisher tag separately
[ ] Confirmed where the signed semi-annual inspection report is stored on-site
Block 3. Suppression tag log
Inspection date | Service company and tech cert | Links or caps replaced | Tag next-due | Report location
________ | ________ | ________ | ________ | ________
________ | ________ | ________ | ________ | ________
Block 4. Disclaimer
We do not dispatch a technician. Ansul is not in our name
This file is not an official certificate.
Prepared by Kitchen Suppression Due (kitchensuppressiondue.com). Source notes read 2026-11-13. We are not a fire-protection contractor; Ansul; NFPA; the fire marshal.
Best-fit self-serve plan for your setup
Best fit for 1 hood: Annual ($39/year, default) or Lifetime ($299 one-time) with 30/7/1-day reminders.
The email contains this worksheet. This plan also emails you 30, 7, and 1 day before the date you entered.
Texas commercial kitchen fire suppression inspection guide
Texas restaurant owners, barbecue pit-house operators, ghost kitchens, and school or hotel foodservice managers track fixed range-hood wet-chemical extinguishing tags on a semi-annual rhythm distinct from exhaust duct grease cleaning. Markel's reading of NFPA 96, read 2026-11-13, notes that commercial cooking fire-extinguishing systems should be maintained at least every six months by properly trained, qualified, and certified persons: https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants
In Texas, contractor registration and technician licensing for fixed fire-extinguisher systems sit under the Texas Department of Insurance State Fire Marshal’s Office (TDI SFMO, https://www.tdi.texas.gov/fire/), while municipal fire marshals across Houston, Dallas-Fort Worth, San Antonio, Austin, and suburban cities enforce local inspection logs and portal submissions. Kitchen Suppression Due is an independent digital checklist publisher—not TDI SFMO, a licensed Texas fire-protection firm, or Ansul.
Use the Texas planning workspace above or Texas checklist pricing to record your hood brand, last tag date, cooking-line changes, and next service target into a clean PDF log with optional 30, 7, and 1 day reminder emails.
Related guidance
Kitchen fire suppression inspection home guide
See the six-month NFPA 96 source note and interactive date calculator.
UL 300 nozzle, cap, and appliance map checklist
Review fryer and charbroiler coverage prompts before your technician arrives.
Hood suppression tag and fusible link log
Track brand nameplates, link replacement dates, and cartridge records.
Multi-location Texas restaurant hood tracker
Manage staggered six-month hood tags across up to five Texas locations.
Kitchen fire and health inspection binder
Organize suppression reports, grease-cleaning receipts, and Class K logs.
Hood cleaning is not the suppression tag
Keep exhaust duct washing separate from fixed wet-chemical service records.
California kitchen suppression inspection guide
Compare multi-state kitchen suppression recordkeeping for western portfolios.
Digital PDF checklist and reminder pricing
Review $19 one-time, $39/year single-hood, and $149/year 5-location plans.
Texas SFMO firm registration and pre-engineered kitchen technician credentials
Texas regulates fire-extinguisher and fixed pre-engineered kitchen suppression contractors through Insurance Code Chapter 6001 and Texas Administrative Code rules administered by TDI SFMO. When scheduling a six-month hood inspection anywhere in Texas, a restaurant manager can ask the service company to confirm its active SFMO Certificate of Registration (ECR) and verify that the dispatched technician holds the appropriate license class (such as a Type K or applicable fixed system license) plus factory training for the hood brand installed over the line.
Asking those questions before the truck rolls prevents an expensive surprise where an unlicensed handyman or grease-washing crew hangs an invalid tag that a municipal fire marshal rejects during a Certificate of Occupancy or annual fire walk-through. Record the firm registration number on your internal booking sheet and verify that the same firm name prints on the final invoice and inspection report.
Understanding Texas service tags vs. yellow or red deficiency status notices
Texas fire-protection rules use structured tagging practices so property managers and local fire marshals can tell at a glance whether a fixed kitchen hood extinguishing system passed routine maintenance or exhibited impairments or nonconformities. While your licensed Texas technician determines the official tag color and status under current SFMO rules, restaurant managers need an operational habit of reading every box on the hanging tag before signing the work order.
Never let a technician walk out the back door during prep rush without handing the manager on duty a legible customer copy of the multi-point inspection report. If the technician notes an overdue hydrostatic cylinder test, grease-caked fusible links, missing nozzle blow-off caps, or a relocated fryer sitting outside nozzle coverage, keep the written deficiency description in your front binder and track the corrective re-inspection date immediately.
Municipal fire marshal portal uploads across DFW, Houston, Austin, and San Antonio
Across fast-growing Texas suburbs—including cities throughout Collin, Denton, Tarrant, Dallas, Harris, Fort Bend, Montgomery, Travis, Williamson, and Bexar counties—municipal fire marshals widely require contractors to submit six-month commercial hood suppression inspection results through electronic compliance portals such as Brycer The Compliance Engine.
In portal-enforced Texas cities, the municipal fire prevention bureau tracks compliance from the contractor’s electronic upload rather than waiting to view the paper tag hanging in your kitchen. Confirm two details when booking your Texas vendor: which municipal AHJ jurisdiction covers your street address (city limits vs. unincorporated county ETJ), and whether the contractor’s flat inspection price includes uploading the passed six-month report to that city’s portal.
High-grease Texas cooking lines, fryers, and mobile food unit hood logs
Texas kitchens running high-capacity chicken or catfish fryers, mesquite or gas charbroilers, Tex-Mex flattops, and commercial smokehouse finishing hoods generate heavy grease vapor that coats fusible links and nozzle caps between semi-annual visits. Under UL 300 wet-chemical system listings, missing rubber or metal blow-off caps allow hardened grease to plug internal nozzle orifices so extinguishing agent cannot atomize properly.
Train kitchen leads to visually confirm during weekly hood wipe-downs that nozzle caps remain seated without ever twisting nozzle aim or hanging ladles, ticket rails, or heat-lamp cords from suppression piping. Mobile food units and commercial food trailers operating in Texas cities with Type I hoods and fixed wet-chemical cabinets face similar semi-annual tag checks during city fire-permit renewals, making a dedicated date tracker equally valuable for trailer operators.
Coordinating gas shutoff valves, building fire alarms, and off-peak testing
During a six-month Texas hood suppression service, the technician tests remote manual pull-station travel, mechanical or solenoid gas-valve shutoff actuation, electrical power disconnects under the canopy, and alarm dry-contact relays where connected to a building fire-alarm panel. If your restaurant sits inside a strip center or mixed-use retail development, tripping the hood microswitch without placing the building fire panel on test can trigger horn-strobes across neighboring suites.
Before your appointment morning, confirm who holds the fire-alarm central-station account (restaurant tenant vs. shopping-center landlord), notify the monitoring center of the test window, and verify afterward that pilot lights, make-up air fans, and alarm supervisory zones returned to normal operating status.
Keeping three separate Texas kitchen safety records ready for walk-throughs
Texas fire marshals and health inspectors routinely ask for three separate maintenance trails that operators accidentally lump together: (1) the semi-annual fixed hood suppression service tag and written report, (2) the NFPA 96 exhaust hood, plenum, riser duct, and rooftop fan grease-cleaning certificate, and (3) the annual maintenance tag and monthly visual check initials on portable Class K and Class ABC fire extinguishers.
Use our suppression vs. hood-cleaning comparison and the audit-ready kitchen binder guide to split those records into separate tabs. Our digital PDF checklist prints your exact Texas kitchen label, brand note, last tag date, and next target date, while $39/year personal plans and $149/year multi-location plans email reminders 30, 7, and 1 day ahead.
Questions
Who regulates fixed kitchen hood suppression contractors in Texas?
The Texas Department of Insurance State Fire Marshal’s Office (TDI SFMO) regulates fire-extinguisher and fixed suppression firm registrations and technician licenses statewide, while local city or county fire marshals enforce on-site and portal inspection records.
How often are Texas commercial kitchen hood suppression systems inspected?
Public guidance citing NFPA 96 (Markel, read 2026-11-13) states fire-extinguishing systems should be maintained at least every six months by qualified, certified personnel. Always verify local Texas municipal fire code rules for your kitchen.
Do Texas cities require electronic portal uploads for kitchen hood inspections?
Many Texas municipal fire marshals require licensed contractors to upload six-month inspection and repair reports to portals such as The Compliance Engine. Ask your contractor whether your address falls inside a portal-enforced city.
Does Kitchen Suppression Due issue Texas SFMO service tags?
No. Only a properly licensed technician inspecting your equipment on site can attach an official service tag. We publish educational guides and email a buyer-completed PDF preparation checklist with optional reminder emails.
Can one multi-location plan track five Texas restaurants on different dates?
Yes. The $149/year Multi-Location Annual Plan and $999 Multi-Location Lifetime Plan each support up to five tracked locations with independent labels and 30/7/1-day reminder schedules.