Semi-annual hood tag & Class K due-date tracker
Commercial kitchens fail fire-marshal paperwork checks when three independent service clocks get lumped onto one calendar line: the six-month fixed wet-chemical hood tag, the annual and five-year hydrostatic schedule on portable Class K extinguishers, and the NFPA 96 exhaust grease-cleaning sticker. Enter your prior tag dates and cylinder stamp years below to generate a clean three-record timeline and exact 30, 7, and 1-day reminder dates.
1. Enter your three kitchen fire records
Separate your fixed hood suppression tag, portable Class K / ABC extinguishers, and NFPA 96 exhaust hood grease cleaning onto one timeline.
2. Unified 3-record compliance timeline
Planning dates calculated from your entries. Confirm binding deadlines with your local Fire Marshal (AHJ) and brand-authorized contractor.
- 30-day booking reminder: 2026-11-23
- 7-day confirmation reminder: 2026-12-16
- 1-day binder & cookline prep alert: 2026-12-22
Hand off this schedule to your PDF binder & email alerts
Send all 4 printable binder blocks to your inbox within 5 minutes and activate 30, 7, and 1-day advance reminders.
As summarized in the public source cited across our site (https://www.markel.com/insights-and-resources/insights/fire-protection-systems-in-restaurants, read 2026-11-13), NFPA 96 states that commercial kitchen fire-extinguishing systems should be maintained at least every six months by properly trained, qualified, and certified persons. Local authorities having jurisdiction (AHJs), state fire marshals, and commercial insurers can enforce stricter rules or electronic reporting deadlines—always treat local official requirements as controlling.
Once your target date looks right, one click carries your state, hood label, cabinet brand note, prior tag date, and next six-month deadline directly into a printable four-block PDF kitchen binder log and automated reminder schedule.
Three separate commercial kitchen fire tags on different clocks
| Kitchen fire record | Routine tag cycle | Cylinder / deep-service milestone |
|---|---|---|
| Fixed UL 300 hood suppression cabinet | Every 6 months (NFPA 96 / 17A) | 12-year wet-chemical tank & hose hydrostatic test |
| Portable Class K wet-chemical extinguisher | Annual licensed tag + monthly visual | 5-year hydrostatic test & wet-chemical recharge (NFPA 10) |
| Portable ABC dry-chemical extinguisher | Annual licensed tag + monthly visual | 6-year internal teardown + 12-year hydrostatic test (NFPA 10) |
| Commercial exhaust hood grease cleaning | 1, 3, 6, or 12 months (NFPA 96 Table 12.4) | Bare-metal scrape when grease gauge reaches 0.078 in (2,000 µm) |
Related guidance
Commercial hood 6-month tag & fusible link tracker
See what cabinet, link stamp, and technician authorization notes belong in your binder.
Joint health & fire marshal hood inspection binder
Organize Tabs 1, 2, and 3 for suppression reports, grease cleaning, and Class K logs.
Kitchen fire suppression inspection cost calculator
Estimate semi-annual tag costs, fusible link parts, and 12-year tank hydrotests.
UL 300 hood nozzle flow-point estimator
Check appliance, plenum, and duct flow points plus semi-annual link counts.
All commercial kitchen suppression calculators
Open the full calculator hub for sizing, service cost, and tag deadline tools.
Printable 4-block PDF & 30/7/1-day reminder plans
Lock in automated advance email reminders for 1 hood ($39/yr) or up to 5 dates ($149/yr).
Exact 6-month anniversary vs. 180-day contract vs. punched tag month
Why do a restaurant manager and a fire inspector occasionally disagree by ten days on whether a hood tag is expired? Physical inspection tags hung on manual pull stations usually feature punched month and year boxes—such as May and November—leading many managers to assume they have until the final calendar day of the sixth month. Meanwhile, certain automated vendor software platforms schedule strictly on 180-day intervals, and municipal compliance portals flag overdue status on the exact calendar anniversary date printed on the prior electronic submission.
Switching between all three calculation rules inside this tracker shows how a strict 180-day cycle lands three to four days earlier than a six-month calendar anniversary, while a month-end punch adds up to three extra weeks. Scheduling your service appointment two to three weeks before the earliest of those three dates eliminates ambiguity completely.
Why portable Class K extinguishers follow a 5-year hydrotest clock, not 6-year
One of the most frequent commercial kitchen compliance mix-ups involves portable fire extinguishers under NFPA 10 (https://www.nfpa.org/codes-and-standards/nfpa-10-standard-development/10). Stored-pressure dry-chemical ABC extinguishers mounted near exits and dry-storage hallways follow an annual licensed tag check, a 6-year internal teardown examination, and a 12-year hydrostatic pressure test.
By contrast, stainless Class K wet-chemical portable extinguishers—installed specifically within thirty feet of commercial fryers and griddles as backup to the fixed UL 300 hood system—follow an annual licensed tag check plus a 5-year hydrostatic pressure test and wet-chemical recharge cycle (with no separate 6-year dry-powder teardown). Tracking both cylinder years side by side prevents a technician visit from leaving an overdue Class K unit hanging next to the fry station.
Aligning fixed suppression visits with NFPA 96 hood grease cleaning
Your exhaust hood grease-cleaning crew scrapes combustible fats from canopy baffles, horizontal ductwork, and rooftop upblast fans on a monthly, quarterly, semi-annual, or annual cadence set by cooking volume under NFPA 96 (https://www.nfpa.org/codes-and-standards/nfpa-96-standard-development/96). Although hood cleaning and suppression maintenance are completely separate trades—detailed on our not-hood-cleaning comparison page—smart operators coordinate their sequence.
Whenever practical, schedule overnight bare-metal hood scraping a few days before your semi-annual suppression technician arrives rather than the night after. If pressure-washing crews knock off a rubber nozzle cap or bump an appliance drop out of alignment, the suppression technician catches and corrects the issue immediately while certifying your fresh six-month tag.
Why 30, 7, and 1-day advance reminders beat a single calendar alert
A calendar alert firing on the morning a six-month suppression tag expires is already too late: brand-authorized fire-protection contractors book daytime cookline windows weeks ahead, especially at quarter-end when municipal portals send batch notices across entire zip codes. Paying rush overtime to beat a re-inspection window easily costs more than a full year of organized tracking, as modeled in our inspection cost calculator.
Our paid reminder workflow sends three deliberate emails before the target date you enter: a 30-day notice so you can confirm brand authorization and book a non-rush morning slot, a 7-day notice to verify cookline access and check nozzle counts from our flow-point estimator, and a 1-day reminder to pull your physical kitchen fire inspection binder onto the manager desk.
State-specific AHJ portal notes and multi-store handoff
Across major jurisdictions—including California, Texas, Florida, and New York—hundreds of city fire prevention bureaus require contractors to upload deficiency-free and deficiency reports into third-party electronic portals within days of turning a wrench. Selecting your state in the tracker carries that state code into your binder label and checkout prefill.
If your prior tag is already past six months, the handoff box automatically sets a clean upcoming appointment target date so you can print your updated four-block binder card today and lock in future reminders the moment your contractor hangs the new tag.
What to keep inside Tabs 1, 2, and 3 on inspection morning
When an insurance loss-control specialist or municipal deputy marshal steps behind the cookline, physical organization speaks louder than searching an email inbox on a phone. Dedicate Tab 1 exclusively to your two most recent semi-annual wet-chemical suppression reports and fusible link replacement notes, dedicate Tab 2 to your signed NFPA 96 bare-metal hood and rooftop fan cleaning certificates with before-and-after duct photos, and dedicate Tab 3 to your annual portable Class K and ABC fire extinguisher service inventory.
Placing our printed four-block summary card right inside the front plastic sleeve shows every shift lead which vendor services which tag and when each independent countdown expires.
Questions
Does a fire marshal give an automatic 30-day grace period after a 6-month tag expires?
Do not count on an unwritten grace period. While some tags punch only the month and year, many municipal electronic portals flag overdue status immediately after six months, and insurance policies require continuous maintenance.
What is the difference between Class K 5-year and ABC 6-year extinguisher service?
Under NFPA 10, wet-chemical Class K portable extinguishers near commercial cooking appliances require a hydrostatic test every 5 years, whereas stored-pressure dry-chemical ABC units require an internal examination at 6 years and a hydrostatic test at 12 years.
Can my suppression technician tag both the hood cabinet and our portable extinguishers?
Often yes, provided the company and technician hold current state portable extinguisher and pre-engineered kitchen suppression licenses—and provided they leave separate, properly itemized tags and report lines for both.
What if my last hood tag date was more than six months ago?
The tracker marks the prior cycle overdue so you know to book a brand-authorized contractor right away, and pre-populates an upcoming appointment target date so you can generate your binder PDF and start fresh 30, 7, and 1-day reminders.
kitchen fire suppression inspection
Next: Choose your printable PDF binder & 30/7/1-day reminder plan